Tek door frame systems combine precision engineering with modular design to support heavy commercial access solutions. These frames are specified where consistent alignment, load capacity, and long term durability are critical.
Architects, engineers, and facility managers rely on standardized profiles and detailed performance data to select the right tek door frame for demanding installations.
| Product Line | Primary Material | Max Door Height | Fire Rating | Typical Use Case |
|---|---|---|---|---|
| Tek Multi Vision | Aluminum | 4000 mm | EI60 | High traffic atria and glazed openings |
| Tek Steel Frame | Steel | 3000 mm | EI120 | Fire rated corridors and shafts |
| Tek Acoustic Frame | Composite | 2400 mm | EI30 | Sound sensitive labs and studios |
| Tek Slim Line | Aluminum | 2700 mm | None | Modern storefronts with minimal sightlines |
Material Options and Performance
Aluminum Tek Door Frame
Aluminum frames resist corrosion, require minimal maintenance, and suit coastal or high humidity projects. They support large glass areas while keeping profiles slim for contemporary architecture.
Steel Tek Door Frame
Steel tek frames deliver high structural strength and superior fire resistance. They are often specified in industrial, parking, and stair enclosures where load and life safety performance are prioritized.
Installation Methods and Coordination
Crane Assisted Installation
For multi ton frames, crane installation reduces manual handling and ensures precise vertical alignment on high rise buildings.
Bolted Field Assembly
On site bolted assemblies allow for adjustments to slab levels and coordination with curtain wall or cladding systems without sacrificing structural continuity.
Acoustic and Thermal Considerations
Thermal Break Profiles
Thermally broken tek frames limit heat transfer, improving overall window performance and reducing condensation risk in colder climates.
Sound Attenuation Ratings
Acoustic gaskets and composite inserts help maintain target Rw levels, particularly important for laboratories, schools, and urban infill projects.
Recommended Practices for Specifying Tek Door Frame
- Define required fire, acoustic, and load ratings before selecting a product line
- Coordinate sectional drawings with structure, slab, and facade consultants
- Confirm crane access or rigging points on site during pre construction
- Include certification, testing, and warranty clauses in the contract documents
- Schedule factory inspections and third party verification for critical projects
FAQ
Reader questions
How do I confirm fire compliance for a tek door frame on site?
Request the manufacturer issued certification document, verify the frame label matches the tested configuration, and ask your certifier to review the as supplied drawings and hardware list.
Can a tek frame be field modified without losing warranty?
Field drilling and cutting are typically restricted; any modification should follow the manufacturer guidance and be logged. Unauthorized alteration may void the extended warranty.
What is the lead time for large quantity orders of tek door frames?
Standard profiles may ship within four weeks, while custom fire rated or acoustic frames often require eight to twelve weeks including testing and factory approval.
Are tek frames compatible with automated door operators and hardware?
Yes, dimensional tables are provided for each line to match actuator forces, pivot positions, and hardware mounting patterns to ensure reliable operation and service access.